
Network Racks and Cabinets

19-Inch Network Racks, Server Cabinets and Wall-Mount Enclosures
Floor-standing server and network cabinets, open-frame racks and wall-mount enclosures, with PDUs, shelves, cable managers and fan kits. We also tell you when a local fabricator beats shipping from Dubai, because a cabinet is mostly air and freight is charged by volume.
| Condition | New (sealed) |
|---|---|
| Ships from | Dubai, UAE |
| Brands | APC by Schneider Electric NetShelter, Vertiv, Rittal, Eaton, Panduit, and quality unbranded cabinets on request |
| Typical models | Wall-mount 6U, 9U, 12U and 15U; floor cabinets from 22U to 47U and 48U; two- and four-post open-frame racks; basic, metered and switched PDUs; fixed and sliding shelves; vertical and horizontal cable managers |
| Form factor | EIA-310 19-inch mounting (1U = 44.45 mm); widths of 600 mm, or 800 mm for extra cable space; depths of 600, 800, 1000 and 1200 mm |
| Performance | Static and dynamic load ratings as declared by the manufacturer; perforated front and rear doors for server airflow, glass or solid doors for wall-mount network enclosures |
| Power | Vertical or horizontal PDUs with IEC C13/C19 or national socket outlets, single- or three-phase; UPS units are sourced through the partner site Computer Hardware Wholesale |
| Testing & grading | Dimensional and visual check against the specification; flat-packed units supplied with an assembly hardware list |
| Warranty basis | Manufacturer terms where applicable, stated per quote |
| Compliance & markings | Manufacturer declarations for load rating, IP rating where the enclosure is sealed, and RoHS; earthing points and bonding kits listed |
| Packing | Flat-packed where the model allows, otherwise assembled and palletised; freight quoted on volume |
| Order quantity | Business volumes only. We quote from a pilot batch up to a full project bill of materials; tell us the quantity per line and we size the sourcing to it. |
| Lead time | Varies with model, condition, quantity and destination; each quote states the lead time we have confirmed with the supplier. |
| Documents | Commercial invoice, packing list with part numbers and lengths, manufacturer datasheets, certificate of origin where required, air waybill or bill of lading |
- Price Beat Promise
- 15+ Years Export Experience
- Serials and Lifecycle Checked
- Export-Screened Orders
Best for
- Branch comms rooms and wiring closets
- Server rooms and small data rooms
- Wall-mount enclosures for retail, hotels and schools
- Integrators who want racks, PDUs and accessories on one order
How we source Network Racks and Cabinets
Size a rack by counting today's equipment in rack units, then adding room for growth, patch panels, cable managers and a shelf or two; a quarter to a half again is a common allowance. Depth matters as much as height. Switches and patch panels fit a 600 mm cabinet, but most rack servers need 1000 mm or more with space behind for power cords, and an 800 mm wide cabinet makes vertical cable management far easier.
Freight is the hidden cost. An assembled 42U cabinet occupies a lot of space for its weight, and air freight on volume can exceed the cabinet's own value. Flat-packed models cut the volume sharply and are the default for sea shipments. For a single cabinet in a city with good metal fabricators, local supply can be the sensible answer, and we will say so. Where a cabinet travels with switches and cabling in a consolidated shipment, it often makes sense to include it.
Think about the room as well as the rack. Dusty sites need filtered fan kits or sealed enclosures; lockable doors and side panels protect equipment in shared spaces; every cabinet should be earthed and bonded. Wall-mount enclosures save floor space in branches and hotels but need a solid wall and enough depth for the switch you plan to fit.
Before you request a quote
What cabinet depth do I need for servers?
Most rack servers need a cabinet at least 1000 mm deep, and 1200 mm gives comfortable room for cables and PDUs. Network-only racks with switches and patch panels can be 600 or 800 mm deep. Check the deepest device's rail length before you order.
Is it worth shipping racks from Dubai?
It depends on volume and destination. Flat-packed cabinets in a consolidated sea shipment are usually economical, while a single assembled cabinet sent by air rarely is. We quote both the freight and the rack so you can compare with local options.
Can you supply PDUs with the right sockets for my country?
Yes. PDUs come with IEC C13 and C19 outlets for equipment, which suit most servers and switches, and the input plug or hard-wiring is specified for your site's single- or three-phase supply.
Related product lines

PoE Injectors and Midspans
802.3af/at/bt · 1G to 10G · 1–24 ports · passive 24/48 V

PoE Access Switches
8–48 ports · PoE/PoE+/802.3bt · 1G or mGig · SFP+ uplinks

Core and Aggregation Switches
24–48 × SFP+/SFP28 · 40/100G QSFP · dual PSU · Layer 3